On-site quality issues in urea granulation don’t need to start by checking “all parameters.” Four main lines each correspond to a set of quantifiable thresholds: For dust, first check the fluidization velocity and bed level; granulation is significantly aggravated when the bed temperature exceeds 118℃. For agglomeration, first check the cooling discharge temperature; urea granules must be cooled to below 40-50℃ for safe storage. For insufficient strength, first check the urea concentration entering the granulator and the final cooling temperature. Biuret is an independent dimension, depending on the temperature and residence time of molten urea; molten residence exceeding 3-5 minutes significantly accelerates biuret formation. The troubleshooting order should be dust first, then agglomeration, then strength, and biuret addressed separately. This is because dust and insufficient cooling can cascade, causing agglomeration and a decrease in apparent strength, while biuret will not automatically decrease even if the other three lines are fixed.

I. Dust: The First Chain Defect in Urea Granulation
Dust in urea granulation is not merely an “appearance problem,” but rather an upstream contributor to agglomeration and reduced strength. Increased fine powder (<1 mm) content will settle into the interparticle spaces during storage and transportation, becoming the starting point for crystal bridges and simultaneously reducing the uniformity of the granulation bed’s permeability. Therefore, dust should be the first point of quality control.
Diagnostic sequence: Air velocity → Bed level → Bed temperature → Urea concentration → UF quality.
Fluidization air velocity is the primary suspect. Excessive air velocity prevents the atomized urea from coating the seed crystals before being directly entrained into the scrubber, causing fine powder to short-circuit with the airflow, increasing dust levels in the finished product. Insufficient air velocity creates localized dead zones in the granulation bed, intensifying particle collision and friction, also causing fine powder to rise. The airflow and level in the cooling bed need to be adjusted inversely: when the level is high, appropriately increase the air velocity and decrease the level to prevent fine powder from being entrained in the finished product.
Bed temperature is the second hard threshold. When the bed temperature exceeds 118℃, the particle surface softens, and the pulverization rate due to collisions and friction between particles accelerates significantly. High bed temperatures also reduce the product’s operational strength, making the finished product more prone to breakage during transport.
Urine concentration and UF (urea-formaldehyde) mass are easily overlooked third factors. A low urine mass fraction entering the granulator indicates insufficient sensible heat and crystallization driving force, resulting in loose particle structure and increased dust. Low UF addition or mass also weakens particle strength, leading to increased pulverization; however, once the UF concentration exceeds 0.45 wt%, the marginal benefit of further increases rapidly diminishes.
Operational Implications: When dust suddenly increases, first check the fluidized bed velocity record and bed pressure difference, then check if the bed temperature exceeds 118℃, and finally verify the urine concentration and UF addition. Do not directly increase the induced draft volume—if dust remains high even at maximum induced draft volume, the problem usually lies in the air velocity distribution or bed condition, not the total air volume.
II. Agglomeration: Cooling endpoint temperature is a higher priority inspection item than coating.
The on-site attribution of urea agglomeration often falls on “packaging temperature,” but packaging temperature is only a result. The real issues to check first are the cooler outlet temperature and the finished product temperature.
Urea exiting the granulator/granulation tower at a temperature far above the safe storage window. Fluidized bed cooling can reduce granules from 70-80℃ to 40-50℃, achieving a product particle size qualification rate of over 98% and preventing agglomeration. Urea granules cooled by fluidized bed cooling are typically cooled to approximately 40℃ before screening and packaging. If the finished product temperature remains above 60℃ before packaging or storage, residual heat drives internal moisture to migrate to the surface, causing slight surface dissolution and recrystallization, leading to rapid crystal bridge formation under storage pressure.
Diagnostic sequence: Cooler outlet temperature → Finished product packaging temperature → Fine powder content → Storage conditions.
A consistently high cooling outlet temperature above 50℃ is the first warning sign of agglomeration. At this point, the matching of cooling air temperature (ideally 15-25℃), airflow, and material layer thickness should be checked, rather than adjusting the coating or anti-caking agent formula first. Fine powder content is the second variable: when the finished product contains more than approximately 1.5% <1 mm fine powder, the fine powder settles to the middle of the material column in the storage silo, where agglomeration begins and worsens within days. Only after the temperature reaches the standard and the fine powder is qualified, if agglomeration still occurs, should the storage pressure and packaging seal be checked.
A common shortcut is adding formaldehyde. Formaldehyde can reduce the moisture absorption and release rates of urea in a short time, thus reducing caking and pulverization, but it alters the moisture absorption kinetics, not the root cause of insufficient cooling endpoint temperature. If the cooling discharge temperature itself is not up to standard, formaldehyde can only postpone the appearance of agglomeration; it cannot eliminate the thermodynamic driving force for crystal bridge formation.

III. Insufficient Strength: First check the “urine entering the granulator,” then check the “particles exiting the cooler.”
Low particle strength in urea granulation follows a completely different attribution path compared to organic fertilizer: binders are not the primary solution; the urine concentration and the final cooling temperature are.
The core of a systematic treatment plan for low urea particle strength under high temperature and humidity conditions in summer lies in two points: increasing the mass fraction of urine entering the granulator and reducing the temperature of the urea particles exiting the cooler. Low urine concentration means that the crystal lattice formed during the crystallization process is not dense enough, resulting in inherently insufficient strength; a high final cooling temperature causes the particles to undergo screening and conveying in a “soft” state, leading to cumulative mechanical damage.
In fluidized bed/rotary drum fluidized bed systems, particle strength comes from the dense accretion structure formed by layer-by-layer coating, not from binder bridging. Therefore, when strength is insufficient, the priority is to adjust the concentration and temperature of the molten urea, the thermal balance of the granulation bed, and the heat exchange capacity of the cooler. Adding formaldehyde (to form methylene diurea polymers to increase molecular weight) is an effective auxiliary measure, but it should be a marginal enhancement after urine concentration and cooling temperature have been achieved, not a structural measure that replaces the first two.
Diagnostic sequence: Urine mass fraction entering the granulator → Cooler outlet temperature → Whether the bed temperature is too high → UF addition amount/mass → Mechanical damage in the screening and conveying process. If the strength problem only occurs in summer, prioritize checking the ambient humidity and cooling capacity; if it exists year-round, prioritize checking the stability of urine concentration in the evaporation system.
IV. Biuret: The only defect that cannot be solved by “fixing the other three lines”
The fundamental difference between biuret and the previous three defects is that dust, agglomeration, and strength can be improved in the granulation or cooling stages by adjusting the wind speed, cooling, and concentration. However, once biuret is formed in the molten state, subsequent processes cannot reverse it. Its only control variables are temperature and residence time.
In industrial terms, biuret formation is slower in molten urea below approximately 145°C, but the key factor is residence time: after approximately 5 minutes in the molten state, biuret formation begins to accumulate significantly; below approximately 3 minutes is a safer operating range, and some processes control the time molten urea is held in the molten state to less than 50 seconds, or even less than 40 seconds. In granulation tower routes, the temperature of molten urea is typically maintained at 130-145°C, with a transport residence time of only 1-5 seconds. Biuret control is achieved through this “high temperature but extremely short residence time.”
Diagnostic sequence: Actual residence time in the melting tank/transport pipeline → Whether the melting temperature consistently exceeds limits → Vacuum degree of the evaporation system and urine concentration → Whether unnecessary heat preservation residence is introduced in the melting section.
A frequently cited issue in compound fertilizer/urea-based compound fertilizer granulation is that adding low-eutectic components such as potassium salts to the formulation may alter the biuret formation behavior. Therefore, the biuret control experience of “pure urea granulation” cannot be directly applied to potassium-containing formulations. If the product formulation involves urea-based compound fertilizer, the investigation of biuret must be tied to the specific formulation, not just based on the temperature-time window of pure urea.
A hard operational boundary: When biuret exceeds the standard, do not attempt to “dilute” or “mask” it by increasing the granulation air volume, increasing the cooling intensity, or adding formaldehyde. These methods affect the physical morphology or strength of the particles, but do not change the biuret molecules already formed in the melting section. The only effective approach is to shorten the residence time of molten urea in the high-temperature zone, lower the melting temperature, or select a technology in the process route that does not produce biuret during granulation.

V. FAQ: Frequently Asked Questions about Urea Granulation Quality Inspection
Q1: Dust and agglomeration occur simultaneously, which should be checked first?
Check dust first, then cooling. When fine powder (<1 mm) exceeds approximately 1.5%, it directly contributes to agglomeration; simultaneously, increased dust is often accompanied by abnormal bed temperature or wind speed, and excessively high bed temperature weakens particle strength and indirectly exacerbates agglomeration. First, check for dust by following the sequence: “Wind speed – Bed level – Bed temperature (118℃ threshold) – Urine concentration,” then confirm whether the cooling discharge temperature has dropped to 40-50℃. Conversely, checking for agglomeration first may lead you to assume cooling is the sole cause, overlooking the upstream variable of dust.
Q2: Is adding formaldehyde effective for decreased particle strength in summer?
No, but it can be used as an adjunct. The systemic causes of strength reduction under high temperature and humidity in summer are urine concentration and the final cooling temperature. Increasing the urine mass fraction entering the granulator and lowering the particle temperature exiting the cooler are structural measures. Formaldehyde increases molecular weight by generating methylene diurea polymers, thus strengthening the particle, but it cannot compensate for the density defects caused by insufficient urine concentration or inadequate cooling capacity.
Q3: Biuret is already exceeding the standard; can increasing cooling or sieving reduce it?
No. Biuret is generated by the thermal shrinkage of urea in the molten state. Cooling and sieving only change the physical state and particle size distribution of the particles, not their molecular composition. The biuret that has already been formed will remain intact in the finished product. Control measures can only be taken in the melting stage: shorten the residence time (less than 3-5 minutes), reduce the melting temperature, or avoid prolonged exposure to high temperatures in the molten state through process selection.